Tender Code: (ICB/EPSS6/MOH-SDG/Spare-Part/MD/05/24
Tender Type: ICB
Closed Date: 10/24/2024 2:00pm
Opening Date: 10/24/2024 2:00pm
Product category: Medical Instruments
Download File: Download
To: All Participants of tender with Ref. No. ICB/EPSS6/MOH-SDG/Spare-Part/MD/05/24
Subject: Clarification and Amendment
Dear Sir/Madam;
We highly appreciate your interest to participate on the tender captioned above and reference is made to your kind request.
We hereby clarify and amend the technical specification as per the attachment and please consider the amendment during your bid document preparation.
We apologize for any inconvenience you may face due to this amendment!
We hope the attached points will clarify your request
With Best Regards
CC:
EPSS
S/N | Item No | Name of Medical Device | Manufacturer | Model | Spare part Name | Clarification/Amendment |
1. | 520 | Refrigerator | Keeler | Battery | The Battery it is for Retinoscope. Not for Refrigerator and Keeler is model | |
2. | 28 | Refrigerator | ARD | RMD-250 | Compressor 1/5HP | The manufacturer is ARDO Medical AG |
3. | 557 | Mechanical Ventilator | Mindray | SV300 | Patient circuit, Adult and Pediatric | The manufacturer is Shenzhen Mindray Biomedical Electronics |
4. | 558 | Operation Table | Mindray | Unibase 30 | Control Board | The manufacturer is Shenzhen Mindray Biomedical Electronics |
5. | 559 | Operating Table | Mindray | Unibase 30 | Remote | The manufacturer is Shenzhen Mindray Biomedical Electronics |
6. | 669 | Anesthesia Machine | Shenzhen Mindray Biomedical Electronics Co.,Ltd | Glory Plus | Soda Lime/CO2 absorber | Change the manufacturer to beijing Aeonmed Co.,Ltd |
7. | 329 | Light- Operating | Dostan SURGICAL | HF.048-M | Control Board | HF.048-M is not model; it is Code |
8. | 29 | Infant Radiant warmer | ARDO Medical AG | Amenic Ardo | Skin Temperature | Model will be Amenic Ardo |
9. | 550 | Oxygen Concentrator | Medical Electronics | J10 | Humidifier | Change Manufacturer to Kencare Medical Systems Limited |
10. | 7 | Infant Radiant Warmer | Air-sheilds | EM81-E | Power Supply Board | Change the manufacturer to Drager Medical and Its Model is WBR – 82 |
11. | 260 | Monitor Fetal | Contec Medical System | CMC8000G | Toco Probe | The Model should be CMS 800G |
12. | 263 | Monitor Fetal | Contec Medical System | CMC8000G | NIBP Cuff, Adult, Pediatric | Name of the device should be Monitor Patient |
13. | 266 | Patient Monitor | Contec Medical System | CM58000G | Reusable Spo2 Probe with extension cable, Adult and Pediatric | The model of the device the should be CMS 8000G |
14. | 267 | Patient Monitor | Contec Medical System | CMS-70A | ECG Cable With Electrode | The Model should be CMS 9200 |
15. | 268 | Patient Monitor | Contec Medical System | CMS-70A | NIBP Cuff, Adult and Pediatric | The Model should be CMS 9200 |
16. | 269 | Patient Monitor | Contec Medical System | CMS-70A | Skin Temperature Probe | The Model should be CMS 9200 |
17. |
270 |
Patient Monitor | Contec Medical System | CMS-70A | Spo2 Probe with extension cable, Adult and Pediatric | The Model should be CMS 9200 |