Tender Code: ICB/EPSS6/SDG&RDF/MD/19/24
Tender Type: ICB
Closed Date: 04/14/2025 2:00pm
Opening Date: 04/14/2025 2:30pm
Product category: Medical Instruments
Download File: Download
To: All Participants of tender with Ref. No. ICB/EPSS6/SDG&RDF/MD/19/24
Subject: Amendment, Clarification and Bid Closing /Opening Date Extension
Dear Sir/Madam;
We highly appreciate your interest to participate on the tender captioned above and reference is made to your kind request.
We hereby amend, clarify and newly added items as per the attachment and please consider the amendment, clarification and added items during your bid document preparation. Additionally Bid closing and opening date is extended to April 14, 2025 G.C 2:00 pm & 2:30 pm respectively.
All the remaining terms, conditions and requirements are same as per the document and the bid price and security validity period shall consider the extended closing/opening date.
We apologize for any inconvenience you may face due to this amendment!
With Best Regards
ENC: 7 Pages
CC:
EPSS
Section 3. Evaluation Methodology and Criteria
Certificate Priority:
Note: For bidders or suppliers offering second-priority products, a Product Registration Commitment Letter must be submitted during the bid opening, and a product application letter from EFDA must be submitted during the bid evaluation period. Failure to submit the Product Registration Commitment Letter at the bid opening or the application letter from EFDA during the bid evaluation period will result in the bidder being considered non-compliant with the second priority.
N.B: A Technical evaluation will conducted for the bidder/supplier offered second priority product if the bidder/supplier offer first priority product fails to meet technical requirements
The following table shows list of regulatory schemes under Stringent Regulatory Authority (SRA) regions
S.No. | Stringent Regulatory Authority (SRA) | Remark | |
1 | US Food and Drug Administration, USA | Valid 510K Notification Letter OR | |
Valid Premarket Approval Certificate (PMA) OR | |||
Valid Certificate for Foreign Government OR | |||
Valid Free Sale Certificate | |||
2 | Ministry of Health, Labor and Welfare, Japan or PMDA (Pharmaceuticals and Medical Device Agency) | Valid Free Sale Certificate OR | |
Market Authorization Certificate | |||
3 | Therapeutic Goods Administration (TGA), Australia | Valid Free sale Certificate OR | |
Market Authorization Certificate | |||
4 | Health Science Authority, Singapore | Valid Free sale Certificate OR | |
Market Authorization Certificate | |||
5 | Competent Authorities from one of the 27 Member States of the European Union who are responsible in Europe for the Regulatory oversight of Medical Device
Please Refer link: |
EU Technical documentation assessment certificate (Annex IX, Chapter II) MDR OR | |
Market Authorization Certificate OR | |||
EC Full quality assurance certificate OR | |||
EC Product Assurance Certificate AND EC Type examination Certificate OR | |||
EC Full Product Quality Assurance Certificate for (MDD & IVDD), Extension from issuing notified body OR | |||
Valid Free sale Certificate | |||
6 | Medicine and Healthcare Products Regulatory Agency, UK | Valid Free sale Certificate OR | |
Market Authorization Certificate | |||
7 | Health Canada, Canada | Valid Free sale Certificate OR | |
Medical device License | |||
8 | Ministry of Food and Drug Safety, South Korea | Valid Free sale Certificate OR | |
Market Authorization Certificate | |||
Market Authorization or Free Sale Certificate from SRA Region For Laundry Machine | |||
1 | USA | ||
2 | Japan | ||
3 | Australia | ||
4 | Singapore | ||
5 | 27 Member States of the European Union | Please Refer link: | |
6 | UK | ||
7 | Canada | ||
8 | South Korea | ||
NB: For bidders or suppliers offering second-priority products, a Product Registration Commitment Letter must be submitted during the bid opening, and a product application letter from EFDA must be submitted during the bid evaluation period. Failure to submit the Product Registration Commitment Letter at the bid opening or the application letter from EFDA during the bid evaluation period will result in the bidder being considered non-compliant with the second priority.
S.N | Item Description | Unit | Qty | Bidder Offer | Status of Compliance | Payment Method |
1 | 1. Generic Name: Automated Blood component centrifuge with consumable and supply | Set | 7 | 90% of purchase order value upon submission of complete shipping document and The remaining 10% after receiving installation,user and technical training and commissioning confirmation letter from health facility | ||
2. Manufacturer: | ||||||
3. Country of origin: | ||||||
4. Model: | ||||||
5. Clinical Purpose/Description: | ||||||
Used for the preparation of blood components from Whole blood donation units | ||||||
6. Technical Specification: | ||||||
The machine shall produce blood componenets a minimum of (red blood cells ,leucoreduced plasma and platelets) in a single centrifugation step (Single run) | ||||||
The machine shall be able to process a minimum of four units/bags of whole blood (450 ml WB) at a time | ||||||
The system should be able to estimate the platelet yield index for the platelets units processed | ||||||
system shall have optional feature to produce leuckoreduced plasma | ||||||
the system shall have an easy to use system interface for operation and control by the laboratory personnel | ||||||
The system shall have a data management/ software that is able to generate critical information related to its operation.The system must have feature to interface with the exiting blood bank information system at the blood bank | ||||||
7. System Configuration Accessories, Spares, Consumables and other componenets: | ||||||
All consumables required for installation and standardization of system to be given free of cost. | ||||||
The Supplier must supply details of manufacturer’s Quality Control data for batches. | ||||||
Introductory kits for training and equipment validation will be given free of charge. Any quality Non conformity on kits the company must replace upon the quantities free of charge | ||||||
The supplier must provide information on the consumables and supplies associated with the testing systems such as MSDS for all products , Package inserts for all products,COA of each lot , Stability data | ||||||
The supplier should provide all complete accessories as per the machine requirement | ||||||
As a minimum each reagent must be labeled with the following information:- Name of assay, the name of the reagent, the product code, the lot number, the expiry date & should have bar-coded identification of reagents. | ||||||
Blood bag collecting 450ml (cassette) (shelf life ≥2 year)—-59,664 | set | 59,664 | ||||
8. Operating Environment; | ||||||
Ambient tem temperature: 15°C to 28°C | ||||||
Relative humidity: 30% to 80% | ||||||
9. Utility Requirements: | ||||||
Input voltage supply is single phase 220-240 VAC, 50HZ | ||||||
10. Standards Certificates & Safety Requirements: | ||||||
Should have FDA or CE certification | ||||||
Should meet electrical safety specification as per IEC class I, It, types BF &CF | ||||||
Should meet general requirement for basic safety & essential performance of the medical electrical equipment as per IEC 60601-1-1 I :20 I 0 ,Specifically; [EC 60601-2-16 & IEC 60601-2-39 | ||||||
11. Installation/Training/Commissioning: | ||||||
The supplier must be install, commissioning and maintain the machines by free of charges . | ||||||
Training should be provided for testing and Quality professionals free of charge and the details of training offered should be specified. | ||||||
The supplier must give consecutive technical training for Blood Bank Service staffs as applicable | ||||||
12. Warranty/ Aftersales service: | ||||||
Installation and user and technical training are mandatory and after sales service of the product must be provided with free of charges. | ||||||
The supplier must be provide minimum of three years warranty including labour and spare part from the date of commissioning. | ||||||
The Supplier should clearly set out a full maintenance and servicing schedule with no costs during warranty period | ||||||
Suppliers must identify in advance a schedule of planned preventative maintenance (PPM) and provide this to the Laboratory Manager at the EBTBS Testing site. This must include a list of the dates for each visit and what will be done at each visit within a week of installation. | ||||||
The Supplier must notify the testing site at least one month in advance of forthcoming routine maintenance visits. The Supplier must remain within the stated schedule. | ||||||
Suppliers must notify the EBTBS at least 3 months in advance of the date of introducing any planned changes to the kit components or instructions for use. | ||||||
Any essential software upgrades must be made available within the maintenance provision at no additional cost. | ||||||
The Supplier’s representative must liaise with laboratory management before commencing work to ensure that proposed activities have met the Authority’s change control requirements and present the minimum disruption and hazard to both parties. | ||||||
All work involving the use of a modem or other electronic data link must be approved in writing by an authorized EBTBS officer before proceeding. | ||||||
The Supplier must provide full records of service/PPM, calibration and equipment upgrades. These must include:Logs of all work carried out during on-site visits or during a modem/data link to the equipment, listings of all equipment/spares used and of changes/upgrades made (including those made by modem/data link) and, an itemized PPM/Service Check-list. | ||||||
Records must be completed, signed and dated by the Supplier’s representative during the visit and a copy handed to the EBTBS authorized officer. | ||||||
The Supplier must carry out documented installation qualification of any new items of equipment installed and/or changes made to existing equipment. | ||||||
After PPM or equipment repair the Supplier must verify that all affected equipment is fully operational before departing the premises. | ||||||
The EBTBS management must be notified of any equipment that is not operational or requires further remedial action, calibration or validation post service/repair. | ||||||
Suppliers must provide written advice of hygiene standards required within the environment the instrumentation is being installed. | ||||||
All records will remain the property of the blood bank | ||||||
If an “in house” calibration of the instrumentation is required, the Supplier must provide written instructions including full methodology, associated equipment and documentation, required frequency and expected outcome. | ||||||
Response times to notification of breakdown must be within 24 hour. | ||||||
Repair of faults or validated backup instrumentation must be provided within 48 hours of notification | ||||||
13 . Documentation: | ||||||
should submit operational and technical Manual in English | ||||||
Certificate of calibration and inspection from factory. | ||||||
14 . Packaging and Labelling; | ||||||
Packing of all the goods must be clearly marked and securely packed. Each goods will be further packed in separate package with all its standard accessories of distinct identification and numbers consecutively. | ||||||
Additional packing and labeling requirements should bear in each package | ||||||
Federal Democratic Republic of Ethiopia Pharmaceuticals Supply Service (EPSS) | ||||||
Tender and Purchase Order No. | ||||||
UMDNS Name and Model of the product | ||||||
PO Box 25-11-276-32-65 | ||||||
Tel: +251-11-276-32-65 | ||||||
Fax: +251-11-275-25-55 | ||||||
Addis Ababa | ||||||
2 | 1. Generic Name: Refrigerated Centrifuge | Set | 15 | 90% of purchase order value upon submission of complete shipping document and The remaining 10% after receiving installation,user and technical training and commissioning confirmation letter from health facility | ||
2. GMDN/UMDN Name: | ||||||
3. Clinical Purpose/Description: | ||||||
General purpose automatic refrigerated centrifuge used for blood component preparation. | ||||||
4. Technical specification | ||||||
General purpose automatic refrigerated centrifuge for blood component preparation, | ||||||
Direct drive motor type, Programmable, microprocessor controlled, 115 programs plus manual mode, Multi stage programs, | ||||||
Floor standing for large capacity, With a capacity of 16 blood bags minimum, Allowable density at least 1200kg/m3, easily moveable, | ||||||
Maximum RPM/RCF 5000/7000Radius programmable for RCF and Integral calculation, | ||||||
Dimension (HxWxD): aprrox. 38X32X40 in | ||||||
Maximum noise 62dB | ||||||
Temperature: +4°C to +22°C | ||||||
9 acceleration profiles, 9 deceleration profiles | ||||||
Timer 10 to 999 minutes, With safety lid lock | ||||||
5. System Configuration Accessories, Spares, Consumables and other components: | ||||||
All consumables required for installation and standardization of system to be given free of cost. | ||||||
The Supplier must supply details of manufacturer’s Quality Control data. | ||||||
The supplier should provide all complete accessories as per the machine requirement | ||||||
6. Operating Environment; | ||||||
Ambient tem temperature: 10°C to 32°C | ||||||
Relative humidity: 30% to 80% | ||||||
7. Utility Requirements: | ||||||
Input voltage supply is single phase 220-240 VAC, 50HZ | ||||||
Voltage Regulator | ||||||
KVA rating matches power consumption of the freezer | ||||||
8. Standards Certificates & Safety Requirements: | ||||||
Should have FDA or CE certification | ||||||
Should meet electrical safety specification as per IEC class I, It, types BF &CF | ||||||
Should meet general requirement for basic safety & essential performance of the medical electrical equipment as per IEC 60601-1-1 I :20 I 0 ,Specifically; [EC 60601-2-16 & IEC 60601-2-39 | ||||||
9. Installation/Training/Commissioning: | ||||||
The supplier must be install, commissioning and maintain the machines by free of charges for three years period. | ||||||
The supplier must give consecutive technical training for Blood Bank Service staffs as applicable | ||||||
10. Warranty/ Aftersales service: | ||||||
Installation and user and technical training are mandatory and after sales service of the product must be provided with free of charges. | ||||||
The supplier must be provide minimum of three years warranty including labour and spare part from the date of commissioning. | ||||||
The Supplier should clearly set out a full maintenance and servicing schedule with no costs during warranty period. | ||||||
Suppliers must identify in advance a schedule of planned preventative maintenance (PPM) and provide this to the Laboratory Manager at the EBTBS Testing site. This must include a list of the dates for each visit and what will be done at each visit within a week of installation. | ||||||
All work involving the use of a modem or other electronic data link must be approved in writing by an authorized EBTBS officer before proceeding. | ||||||
The Supplier must provide full records of service/PPM, calibration and equipment upgrades. These must include:Logs of all work carried out during on-site visits or during a modem/data link to the equipment, listings of all equipment/spares used and of changes/upgrades made (including those made by modem/data link) and, an itemized PPM/Service Check-list. | ||||||
Records must be completed, signed and dated by the Supplier’s representative during the visit and a copy handed to the EBTBS authorized officer. | ||||||
The Supplier must carry out documented installation qualification of any new items of equipment installed and/or changes made to existing equipment. | ||||||
After PPM or equipment repair the Supplier must verify that all affected equipment is fully operational before departing the premises. | ||||||
The EBTBS management must be notified of any equipment that is not operational or requires further remedial action, calibration or validation post service/repair. | ||||||
Suppliers must provide written advice of hygiene standards required within the environment the instrumentation is being installed. | ||||||
All records will remain the property of the blood bank | ||||||
If an “in house” calibration of the instrumentation is required, the Supplier must provide written instructions including full methodology, associated equipment and documentation, required frequency and expected outcome. | ||||||
Response times to notification of breakdown must be within 24 hour. | ||||||
11. Documentation: | ||||||
should submit operational and technical Manual in English | ||||||
Certificate of calibration and inspection from factory. | ||||||
12. Packaging and Labelling; | ||||||
Packing of all the goods must be clearly marked and securely packed. Each goods will be further packed in separate package with all its standard accessories of distinct identification and numbers consecutively. | ||||||
Additional packing and labeling requirements should bear in each package | ||||||
Federal Democratic Republic of Ethiopia Pharmaceuticals Supply Agency (EPSA) | ||||||
Tender and Purchase Order No. | ||||||
UMDNS Name and Model of the product | ||||||
PO Box 25-11-276-32-65 | ||||||
Tel: +251-11-276-32-65 | ||||||
Fax: +251-11-275-25-55 | ||||||
Addis Ababa |