Bid Amendment and Closing/Opening Date Extension:(ICB/EPSS6/Routine,SRHB & SG/MD/26/23 )
Tender Code: :(ICB/EPSS6/Routine,SRHB & SG/MD/26/23
Tender Type: ICB
Closed Date: 02/14/2024 2:00pm
Opening Date: 02/14/2024 2:30pm
Product category: Medical Instruments
Download File: Download
To: All Participants of tender with Ref. No. ICB/EPSS6/Routine, SRHB & SG/MD/26/23
Subject: Bid Amendment and Closing/Opening Date Extension;
Dear Sir/Madam;
We highly appreciate your interest to participate on the tender captioned above and reference is made to your kind request.
- We hereby amend the technical specification for item 32 and 56 as per the attachment and please consider the amendment during your bid document preparation (see attachment).
- The Bid Closing and Opening Date is extended to February 7, 2024 GC 2:00 pm and 2:30 pm respectively.
All the remaining terms, conditions and requirement are same as per the bid document and the bid price & bid security validity period shall consider the extended closing/opening date. We apologize for any inconvenience you may face due to this amendment!
With Best Regards
INC. 04 Page.
CC:
- Deputy Director General (Inbound Logistics)
- Medical Device Tender Management Case Team
- Archive
EPSS
Item No. | Item Details |
32 | 1. Generic Name: Light – Operating, Ceiling |
Bidder: | |
Manufacturer Name: | |
Manufacturer Country of Origin: | |
Quoted Product Model: | |
Product Certificate from SRA Region: | |
Country of Origin: | |
EFDA Product Certificate: | |
2. GMDN/UMDN Code/Name: | |
3. Clinical Purpose/Description: | |
A ceiling type provides an optimal shadow free lighting for carrying out surgical procedures in an emergency environment. | |
4. Technical Specification: | |
Ceiling mount: one large copula (70 cm) and one satellites (50 cm) | |
Spring balanced articulating arm, two sections approx 0.70 m + 1.00 m | |
Vertical adjustment, approx 1.00m | |
The highly counter balanced mechanism to fix the dome at any position, easy maneuverable free up & down & swing movements & freely rotatable at any angle. | |
Light source: LED | |
Maximum Light Output in 1m (lux) :160,000 | |
Applicable Working Distances from Light head to Surgical Area (cm): 70 ~ 150 | |
Color temperature: ≥ 4300 K | |
Total Irradiance Ee (W/m2): 520 | |
Heat filtrating: 99% | |
Dimming Range 30 – 100°/o | |
LED life time: approx 50000 Hr | |
5. System Configuration Accessories, Spares, Consumables and other components: | |
1 x Ceiling anchoring ring, extension and fixation material | |
1 x Sterilizable removable handle | |
6. Operating Environment; | |
Operating Temperature:+10 °C to + 32°C | |
Relative humidity : < 85% | |
7. Utility Requirements: | |
Electrical Power Supply: 100 – 230VAC | |
8. Standards and Safety Requirements: | |
Should meet IEC-60601(Or Equivalent) General Requirements of Electrical Safety | |
9. Installation, Training and Commissioning: | |
The supplier must provide installation, and commissioning of the device at health Facility | |
The supplier must provide on sight technical and end user training | |
10. Warranty and After Sale service: | |
The supplier must be providing minimum of Two years warranty including labor and spare part from the date of commissioning. | |
After basic warranty the supplier must agree for providing after sales service on agreement base | |
11. Documentation: | |
User and service manual in English | |
12. Packaging and Labeling; | |
Packing of all the goods clearly marked and securely packed. | |
Each goods will be further packed in separate package with all its standard accessories of distinct identification and numbers consecutively. | |
Each item with all accessories /spare part shall be configured and packed in one unit. | |
Federal Democratic Republic of Ethiopia Pharmaceuticals Supply Service (EPSS) | |
Tender and Purchase Order No. | |
Name and Model of the product | |
PO Box 25-11-276-32-65 | |
Tel: +251-11-276-32-65 | |
Fax: +251-11-275-25-55 | |
Addis Ababa | |
56 | 1. Generic Name: Warmer – Radiant, Infant |
Bidder: | |
Manufacturer Name: | |
Manufacturer Country of Origin: | |
Quoted Product Model: | |
Product Certificate from SRA Region: | |
Country of Origin: | |
EFDA Product Certificate: | |
2. GMDN/UMDN Code/Name:: | |
3. Clinical Purpose/Description: | |
Infant radiant warmer used for the treatment of hypothermia on infants. | |
4. Technical Specification: | |
Mobile, mounted on 4 double swiveling castors wheels, 2 with brakes. | |
Table surface: conductive mattress with infant head/shoulder support. | |
Mattress cover: waterproof and washable. | |
Resistant to cleaning with chlorine based solution and flame retardant. | |
Side boards transparent acryl, drop down and lockable. | |
Bassinet trolley; bed should be tilt able and have provision for X-Ray cassette holder. | |
Markings on the bassinet and X-Ray cassette holder are mandatory to enable proper positioning of the baby while doing the X-Ray. | |
Bed can tilt continuously up to ± 12° for Trendelenburg | |
Under table 2 storage drawers. | |
Side rails allow for mounting of accessories. | |
Hood suspended above the table integrates heating element and overhead light. | |
Overhead light: LED | |
Base should be height adjustable with electrical foot switches on both sides. | |
Display with LCD screen for displaying skin temperature and heat power separately. | |
Feather touch operation with large digital display and comprehensive alarms. Control Panel should be liquid proof and allow easy and hygienic disinfection | |
Heating element: emitter with parabolic reflector and protected by metal grid Control unit allows air and skin temperature preset (LCD indicator) and drives radiant heater Output (servo and manual) | |
Integrated timer: 1 to 59 min | |
Temperature range: skin: 34 to 38 deg C (user pre-settable) | |
Monitoring of skin temperature by means of sensor, range: 30oC to 40oC | |
Heater output: 0 to 100% in increments of 5% | |
Audio and visual alarms for: Power failure, Probe failure or disconnected, Heater failure,Temperature higher or lower than set temperature. | |
Display reports systems errors, sensor failure. | |
Control unit: audiovisual alarms according to timer and temperature presets avoiding overheating | |
Protection: OVP, earth leakage protection. | |
5. System Configuration Accessories, Spares, Consumables and other components: | |
1 x Mattress | |
3 x skin temperature probe (including connection cable) | |
1 x spare heating element | |
Skin adhesive for fixing probe – 100 units | |
Acrylic helmet | |
5 x spare fuses | |
Eye pads for use during phototherapy – 50 units | |
IV pole | |
6. Operating Environment; | |
Operating Temperature:+10 °C to + 32°C | |
Relative humidity : < 85% | |
7. Utility Requirements: | |
Electrical Power Supply: 220VAC +/-10%,50Hz | |
8. Standards and Safety Requirements: | |
Shall meet IEC-60601 ( Bs equivalent) General Requirements of electrical Safety | |
9. Installation, Training and Commissioning: | |
The supplier must provide commissioning of the device at health Facility | |
The supplier must provide on sight technical and end user training | |
10. Warranty and After Sale service: | |
The supplier must be provide minimum of Two years warranty including labor and spare part from the date of commissioning. | |
After basic warranty the supplier must agree for providing after sales service on agreement base | |
11. Documentation: | |
User and service manual in English | |
12. Packaging and Labeling; | |
Packing of all the goods clearly marked and securely packed. | |
Each goods will be further packed in separate package with all its standard accessories of distinct identification and numbers consecutively. | |
Additional packing and labeling requirements should bear in each package | |
Each item with all accessories /spare part shall be configured and packed in one unit. | |
Federal Democratic Republic of Ethiopia Pharmaceuticals Supply Service (EPSS) | |
Tender and Purchase Order No. | |
Name and Model of the product | |
PO Box 25-11-276-32-65 | |
Tel: +251-11-276-32-65 | |
Fax: +251-11-275-25-55 | |
Addis Ababa |